5 Repair
5.4.2 Replacing the swing
Continued
Refitting the axis-2 motor
1
2
3
4
Continues on next page
356
Action
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
Check the cooling pad.
Replace if damaged, as shown in the following
step.
Remove the screws.
Replace with a new cooling pad and then refit the
screws.
Orient the motor correctly and fit it into the swing.
Tip
Bend the motor signal cable back towards the
swing support.
© Copyright 2021-2023 ABB. All rights reserved.
Note
Cooling pad for axis-1 and -2 mo-
tors: 3HAC071020-001
xx1800003603
Screw: M3x5 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 1.2 Nm
xx1800003026
Motor orientation: orient the motor
according to the figure below, in
regard to the encircled motor con-
nector.
xx1800003027
Product manual - CRB 1100
3HAC078007-001 Revision: J