ABB CRB 1100 Product Manual page 257

Table of Contents

Advertisement

2
3
4
Refitting the connector interface plate
1
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Reconnect the connectors.
SMB.P7
SMB.J1
SMB.J2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Refit the SMB cover to the base.
Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
© Copyright 2021-2023 ABB. All rights reserved.
5.3.2 Replacing the lower cable package
Note
Tightening torque: 0.3 Nm
xx1800002468
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Tightening torque: 1.2 Nm
xx1800002467
Note
Continues on next page
5 Repair
Continued
257

Advertisement

Table of Contents
loading

Table of Contents