3
Separating the upper cable harness from the axis-2 gearbox
1
2
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Valid for CRB 1100-4/0.58
Remove the plug screw and washer on the ex-
tender unit to access the cable package locking
screw on the axis-4 gearbox and then loosen the
locking screw.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the cable bracket.