ABB CRB 1100 Product Manual page 391

Table of Contents

Advertisement

Reconnecting the connectors at the division point
1
2
3
4
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Insert the female header of the connectors to the
connector plate.
Reconnect the connectors.
J2.FB2,3,4,5,6
J2.MP3,4,5/6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Refit the connector plate.
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the lower arm
Continued
Note
xx1800003029
xx1800003030
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 0.8 Nm
xx1800002489
Continues on next page
391

Advertisement

Table of Contents
loading

Table of Contents