Reconnecting the connector J2.FB2
1
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Use a sonic tension meter to measure the timing
belt tension.
If the timing belt tension does not meet the require-
ment, loosen the motor screws and readjust.
Remove the adjustment screw from the motor.
Reconnect the connector.
MP2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Action
Insert the female header of the J2.FB2 connector
to the connector plate.
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.7.2 Replacing the axis-2 motor
Continued
Note
Used belt: 163-174 Hz
New belt: 180-229 Hz (for reference
only)
xx1900000010
xx1800002495
Note
xx1800002491
Continues on next page
499