5 Repair
5.4.2 Replacing the swing
Continued
Consumable
Grease
Grease
Locking liquid
Sealing compound
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Removing the swing
Use these procedures to remove the swing.
Preparations before removing the swing
1
Continues on next page
320
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
© Copyright 2021-2023 ABB. All rights reserved.
Article number
Note
3HAC029132-001
FM 222
-
Castrol Molub. Alloy 777-1 NG
Used to lubricate bearings on the
swing support and lower arm
support.
-
Loctite 2400 (or equivalent Loctite
243)
3HAC026759-002
Sikaflex 521 FC
Note
Note
Calibrating axis 6 always requires tools to
be removed from the mounting flange (also
for reference calibration) since the mount-
ing flange is used for installation of the
calibration tool.
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
Note
Reference calibration
664.