ABB CRB 1100 Product Manual page 371

Table of Contents

Advertisement

Disconnecting the axis-3 motor connectors
1
2
3
4
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the lower arm support cover.
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
Slide the connectors out of the connector plate
and disconnect the connectors.
FB3
MP3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the lower arm
Continued
Note
xx1800003003
xx1800003004
xx1800003005
Continues on next page
371

Advertisement

Table of Contents
loading

Table of Contents