Refitting the swing covers
1
2
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Reconnect the connectors.
J2.FB2,3,4,5,6
J2.MP3,4,5/6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Refit the connector plate.
Action
Apply grease to the cable package, cover all
moving area of the package.
Apply grease to the covers that have contacting
area with the cable package.
© Copyright 2021-2023 ABB. All rights reserved.
5.8.1 Replacing the axis-1 gearbox
Note
xx1800003030
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 0.8 Nm
xx1800002489
Note
Continues on next page