5 Repair
5.7.2 Replacing the axis-2 motor
Continued
2
3
Refitting the motor
Use these procedures to refit the axis-2 motor.
Refitting the cooling pad
1
2
Refitting the axis-2 motor
1
Continues on next page
496
Action
Loosen the cooling pad bracket screws on the
motor flange.
Use a plastic sheet with caution to remove the
cooling pad together with the bracket from the
motor. Pay attention not to scratch the motor or
damage the pad.
Action
Attach the cooling pad together with the bracket
to the motor.
Make sure the bracket does not exceed the motor
flange and the screw holes are aligned.
Refit the cooling pad bracket.
Action
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
© Copyright 2021-2023 ABB. All rights reserved.
Note
xx1800003026
Note
Cooling pad for axis-1 and -2 mo-
tors: 3HAC071020-001
Screw: M3x5 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 1.2 Nm
xx1800003026
Note