Loosening the cable package from axis-1 gearbox
1
2
3
Disconnecting the connectors at the division point
1
2
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Access the cable package locking screw on the
axis-1 gearbox from the swing and then loosen
the locking screw.
Remove the locking screw.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Disconnect the connectors.
J2.FB3,4,5,6
J2.MP3,4,5/6
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Note
xx1800003032
Note
xx1800002497
Continues on next page