ABB CRB 1100 Product Manual page 507

Table of Contents

Advertisement

5
6
7
Product manual - CRB 1100
3HAC078007-001 Revision: J
Action
Remove the screws and washers.
Carefully lift out the motor.
CAUTION
A cooling pad is attached to the motor, which may
stick to the casting. Always use a plastic sheet
with caution to remove the pad from the casting.
Pay attention not to scratch the casting or damage
the pad.
Remove the timing belt from its groove on the
motor.
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.7.3 Replacing the axis-3 motor
Continued
Note
xx1800003009
Cooling pad location
xx1800003604
xx1800003010
Continues on next page
507

Advertisement

Table of Contents
loading

Table of Contents