ABB Robotics IRB 1520 Product Manual page 84

Table of Contents

Advertisement

3 Maintenance
3.3.2 Inspecting the oil level, axis 2 gearbox
Continued
Inspecting oil level, axis 2 gearbox
Use this procedure to inspect the oil level in the axis 2 gearbox. A suspended robot
must be taken down and secured standing on the floor for inspection.
1
2
3
4
5
6
7
84
Action
WARNING
Handling gearbox oil involves several safety
risks, see
Gearbox lubricants (oil or grease)
on page
32.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
CAUTION
The gearbox can contain an excess of
pressure that can be hazardous. Open the
oil plug carefully in order to let out the ex-
cess pressure.
If the robot is suspended, lift it down from
its suspended position and secure it on the
floor.
Then open the oil plug for inspection.
Measure the oil level at the oil plug hole.
Required oil level:
23 mm ± 3 mm below the lower edge
of the oil plug hole.
Add oil if required.
Refit the oil plug.
Note
Before refitting the oil plug in the gearbox,
always replace the oil plug sealing washer
with a new one. If not there is a risk of
leakage.
© Copyright 2012-2020 ABB. All rights reserved.
Note
See
Lifting and turning a suspended
mounted robot on page
52.
See
Location of axis 2 gearbox on
page
83.
How to fill oil is described in section
Changing the oil, axis-2 gearbox
on page 113
Tightening torque:
10 Nm
Product manual - IRB 1520