ABB Robotics IRB 1520 Product Manual page 62

Table of Contents

Advertisement

2 Installation and commissioning
2.3.5 Setting the system parameters for a suspended or tilted robot
Continued
Defining the parameter in the IRC5 software
The value of the system parameters that define the mounting angle must be
redefined when changing the mounting angle of the robot. The parameters belong
to the type Robot, in the topic Motion.
How to calculate a new value is detailed in
The system parameters are described in Technical reference manual - System
parameters.
The system parameters are configured in RobotStudio or on the FlexPendant.
62
© Copyright 2012-2020 ABB. All rights reserved.
Mounting angles and values on page
Product manual - IRB 1520
3HAC043435-001 Revision: L
59.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents