Page 2
1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.
Page 3
The HS3864ECH61H is a user system interface cable that connects an H8/3864 series, H8/3887 series E6000 emulator (HS3880EPI60H; hereinafter referred to as the emulator) to the IC socket for a QFP-80A package (package code: FP-80A) for the H8/3864 series MCU on the user system.
Section 1 Configuration...1 Section 2 Connection Procedures ...4 Connecting User System Interface Cable to Emulator Station ... 4 Connecting User System Interface Cable to User System ... 5 2.2.1 Installing IC Socket ... 5 2.2.2 Soldering IC Socket ... 5 2.2.3 Inserting Cable Head ...
Section 1 Configuration Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3864ECH61H user system interface cable for the FP-80A package. UTION...
Page 6
To emulator station Screws (M2 x 8 mm) with flat washers Socket cover Figure 1 HS3864ECH61H User System Interface Cable Cable body IC socket User system Screws (M2 x 12 mm) with flat washers (for fastening cable head) Cable head...
Page 7
Table 1 lists the HS3864ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3864ECH61H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2 x 12 mm) Screws (M2 x 8 mm) Documentation Quantity Remarks...
Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY.
Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY.
2.2.4 Fastening Cable Head 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Page 11
Fasten the user system interface cable head to the IC socket for an FP-80A package on the user system with the four screws (M2 tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
2.2.5 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body...
Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Unit: mm Tolerance: –0.5 mm Figure 6 Dimensions for User System Interface Cable Head...
Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head IC socket (IC149-080-017-B5 User system manufactured by YAMAICHI ELECTRONICS Co. Ltd.) Figure 7 Resulting Dimensions after Connecting User System Interface Cable Unit: mm Tolerance: –0.5 mm...
Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Page 17
Screws (M2 x 8 mm) with flat washers Socket cover Pin 1 IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 8 Installing MCU to User System...
Section 4 Verifying Operation 1. When using the H8/3864 series, H8/3887 series E6000 emulator (HS3880EPI60H), turn on the emulator according to the procedures described in the H8/3864 series, H8/3887 series E6000 Emulator User's Manual (HS3880EPI60HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins.
Page 19
Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. Ω R1 1 M HCU04 To E6000 emulator HCU04 Ω R2 270 OSC1 OSC2 System clock oscillator Figure 9 System Clock Oscillator and Subclock Input Specifications 0.8 Vcc 0.3 Vcc 55 ns max.
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.