Low power applications for ra6 and ra4 groups (41 pages)
Summary of Contents for Renesas FP-100A
Page 1
On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
Page 2
Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
Page 3
H8/3834 Series, H8/3814 Series, H8/3877 Series FP-100A User System Interface Cable (HS3834ECF61H) for E6000 Emulator User’s Manual H8/3834 Series, H8/3814 Series, H8/3877 Series FP-100A Rev.4.0 2003.04...
Page 4
1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.
Page 5
The HS3834ECF61H is a user system interface cable that connects an H8/300L series E6000 emulator (HS3L08EPI60H; hereinafter referred to as the emulator) to the IC socket for a FP-100A package for the H8/3834 series, H8/3814 series, or H8/3877 series MCU on the user system.
Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Cable to Emulator Station ... 3 Connecting User System Interface Cable to User System ... 5 2.2.1 Installing IC Socket ... 5 2.2.2 Soldering IC Socket ... 5 2.2.3 Inserting Cable Head ...
Section 1 Configuration Use an IC149-KS-11113-0 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100A package IC socket on the user system. Figure 1 shows the configuration of the HS3834ECF61H user system interface cable for the FP-100A package. Figure 1 HS3834ECF61H User System Interface Cable...
Page 8
Cable body Cable head IC socket Socket cover Screws (M2.5 x 11 mm) Documentation Quantity Remarks Flat cable For the FP-100A package For installing an FP-100A-packaged MCU For fastening cable head (with two flat washers) User’s manual for HS3834ECF61H (this manual)
Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
Page 10
Figure 2 Connecting User System Interface Cable to Emulator Station...
Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100A package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3.
Check conduction with a tester and re-solder the socket if necessary. Fasten the user system interface cable head to the IC socket for an FP-100A package on the user system with the two screws (M2.5 tightened a little at a time, alternating between the sides.
Page 13
Figure 3 Connecting User System Interface Cable to User System...
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100A package (IC149-KS-11113-0: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head...
Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable...
Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Section 4 Verifying Operation 1. When using the H8/300L series E6000 emulator (HS3L08EPI60H), turn on the emulator according to the procedures described in the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins.
Page 20
Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. Ω R1 1 M HCU04 To E6000 emulator HCU04 Ω R2 270 OSC1 OSC2 System clock oscillator Figure 9 System Clock Oscillator and Subclock Input Specifications 4.
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.