SWE:EGAT:TRAC1:STAT1 ON (see
STATe<range>]
Activates tracing for range 1 of trace 1.
SWE:EGAT:TRAC1:STAR1 3ms (see
STARt<range>
Sets the starting point for range 1 on trace 1 at 3 ms.
SWE:EGAT:TRAC1:STop1 5ms (see
STOP<range>
Sets the stopping point for range 1 on trace 1 at 5 ms.
SWE:EGAT:TRAC1:PER 5ms (see
on page 795)
Defines the period for gated triggering to 5 ms.
Adjust Settings ← APD
Adjusts the level settings according to the measured difference between peak and min-
imum power for APD measurement or peak and mean power for CCDF measurement
in order to obtain maximum power resolution. Adjusts the reference level to the current
input signal. For details see also the
Remote command:
CALCulate<n>:STATistics:SCALe:AUTO ONCE
Softkeys for CCDF Measurements
CCDF.......................................................................................................................... 321
CCDF
Activates the function to measure the complementary cumulative distribution function
(CCDF) and opens a submenu.
User Manual 1175.7068.02 ─ 12
on page 795)
on page 795)
on page 796)
Percent
Marker............................................................................................. 322
Res
BW.........................................................................................................322
# of
Samples................................................................................................. 322
└ Scaling.......................................................................................................... 323
x-Axis Ref
Level..................................................................................323
x-Axis
Range...................................................................................... 323
Range Log 100
Range Log 50
Range Log 10
Range Log 5
Range Log 1
Range Log
Range Linear
Range Lin.
y-Axis Max
Value................................................................................ 325
y-Axis Min
Value................................................................................. 325
y-Unit % /
Abs..................................................................................... 325
Default
Settings.................................................................................. 325
Adjust
Settings....................................................................................326
Gated Trigger
(On/Off).................................................................................. 326
Gate
Ranges.................................................................................................326
Adjust
Settings.............................................................................................. 327
[SENSe:]SWEep:EGATe:TRACe<k>[:
[SENSe:]SWEep:EGATe:TRACe<k>:
[SENSe:]SWEep:EGATe:TRACe<k>:
[SENSe:]SWEep:EGATe:TRACe<k>: PERiod
Adjust Ref Lvl
softkey.
on page 797
dB....................................................................323
dB......................................................................323
dB......................................................................323
dB........................................................................324
dB........................................................................324
Manual................................................................... 324
%........................................................................324
Unit.........................................................................325
Spectrum Measurements
Measurements
321

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents