R&S ESR Series User Manual page 877

Emi test receiver
Table of Contents

Advertisement

®
R&S
ESR
Parameters:
<State>
Example:
Manual operation:
Marker Demodulation
Commands useful to configure the marker demodulation described elsewhere:
[SENSe:]DEMod:SQUelch:LEVel
[SENSe:]DEMod:SQUelch[:STATe]
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation:CONTinuous
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation:HOLDoff
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation:SELect
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation[:STATe]
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation:CONTinuous <State>
This command turns continuous demodulation of the signal at the marker position in
the frequency domain on and off.
Thus acoustic monitoring of the signals can be performed.
In the time domain continuous demodulation is always on.
Suffix:
<n>
<m>
Parameters:
<State>
Example:
Manual operation:
CALCulate<n>:MARKer<m>:FUNCtion:DEModulation:HOLDoff <Duration>
This command defines for how long the the signal at the marker position is demodula-
ted.
User Manual 1175.7068.02 ─ 12
Remote Commands in Spectrum Analyzer Mode
ON | OFF
*RST:
OFF
CALC:DELT:FUNC:PNO ON
Switches on the phase-noise measurement with all delta mark-
ers.
CALC:DELT:FUNC:FIX:RPO:X 128 MHZ
Sets the frequency reference to 128 MHz.
CALC:DELT:FUNC:FIX:RPO:Y 30 DBM
Sets the reference level to +30 dBm
See
"Phase Noise On/Off"
on page 648
on page 649
.
Selects the measurement window.
Selects the marker.
ON | OFF
*RST:
OFF
CALC2:MARK3:FUNC:DEM:CONT ON
Switches on the continuous ' demodulation.
See
"Continuous Demod (span > 0)"
Remote Control
on page 418
....................................874
..........................................874
............................................875
........................................... 875
on page 420
874