Example:
Manual operation:
CALCulate<n>:MARKer<m>:Y:PERCent <Probability>
This command positions the selected marker to the given probability.
If you use the command in combination with a delta marker, that delta marker is turned
into a normal marker.
Note: The command is only available for CCDF measurements. You can query the
associated level value with CALCulate<n>:MARKer<m>:X.
Suffix:
<n>
<m>
Parameters:
<Probability>
Example:
Manual operation:
CALCulate<n>:THReshold <Threshold>
This command defines a threshold value for the marker peak search.
A threshold line is automatically turned on.
Suffix:
<n>
Parameters:
<Threshold>
Example:
Manual operation:
CALCulate<n>:THReshold:STATe <State>
This command turns the threshold line for the marker peak search on and off.
Suffix:
<n>
User Manual 1175.7068.02 ─ 12
Remote Commands in Spectrum Analyzer Mode
*RST:
POINts
CALC:MARK:X:SSIZ STAN
Sets the measured value step size.
See
"Stepsize Standard"
See
"Stepsize Sweep Points"
.
Selects the measurement window.
Selects the marker.
Range:
0 to 100
Default unit: PCT
CALC1:MARK:Y:PERC 95PCT
Positions marker 1 to a probability of 95 %.
See
"Percent Marker"
on page 322
.
irrelevant
The unit depends on CALCulate<n>:UNIT:POWer.
*RST:
(STATe to OFF)
CALC:THR -82DBM
Sets the threshold value to -82 dBm.
See
"Threshold"
on page 206
.
irrelevant