R&S ESR Series User Manual page 286

Emi test receiver
Table of Contents

Advertisement

®
R&S
ESR
Example
Figure 6-6: Sweep list using Fast SEM mode
In
Figure
separately defined ranges are combined to 2 sweep ranges internally.
6.1.1.6
Measuring Spurious Emissions
The Spurious Emissions measurement defines a measurement that monitors unwan-
ted RF products outside the assigned frequency band generated by an amplifier. The
spurious emissions are usually measured across a wide frequency range. The Spuri-
ous Emissions measurement allows a flexible definition of all parameters. A result table
indicates the largest deviations of the absolute power from the limit line for each range,
and the results can be checked against defined limits automatically.
User Manual 1175.7068.02 ─ 12
6-6, a sweep list is shown for which Fast SEM is activated. The formerly 5
Spectrum Measurements
Measurements
283