R&S ESR Series User Manual page 314

Emi test receiver
Table of Contents

Advertisement

®
R&S
ESR
The second picture shows the corresponding CISPR APD function.
The probability of time at 10e-2 corresponds to the duty cycle of 1 %. The maximum
level of -20.145 dBm corresponds to the peak level that has been measured in spec-
trum mode.
Softkeys for CISPR APD Measurements
Functions to configure CISPR APD measurements described elsewhere:
"Percent Marker"
"Res BW Manual"
"Scaling"
"Adjust Settings"
Acquisition
Acquisition Time
Defines the measurement time for CISPR APD measurements.
Remote command:
[SENSe:]SWEep:TIME
User Manual 1175.7068.02 ─ 12
on page 322
on page 184
on page 317
on page 320
Time.......................................................................................................... 311
on page 639
Spectrum Measurements
Measurements
311