R&S ESR Series User Manual page 713

Emi test receiver
Table of Contents

Advertisement

®
R&S
ESR
<k>
Parameters:
<Mode>
Example:
CALCulate<n>:LIMit<k>:CONTrol:OFFSet <Offset>
This command defines an offset for a complete limit line.
Compared to shifting the limit line, an offset does not actually change the limit line defi-
nition points.
Suffix:
<n>
<k>
Parameters:
<Offset>
Example:
Manual operation:
CALCulate<n>:LIMit<k>:CONTrol:SHIFt <Distance>
This command moves a complete limit line horizontally.
Compared to defining an offset, this command actually changes the limit line definition
points by the value you define.
Suffix:
<n>
<k>
Parameters:
<Distance>
User Manual 1175.7068.02 ─ 12
1...8
Selects the limit line.
ABSolute
Limit line is defined by absolute physical values (Hz or s).
RELative
Limit line is defined by relative values related to the center fre-
quency (frequency domain) or the left diagram border (time
domain).
*RST:
ABSolute
CALC:LIM2:CONT:MODE REL
Defines the x-axis of limit line 2 as relatively scaled.
.
Selects the measurement window.
1...8
Selects the limit line.
Numeric value that defines the offset.
The unit of the offset depends on the scale of the x-axis.
*RST:
0
CALC:LIM2:CONT:OFFS 100us
Sets the X offset for limit line 2 (defined in zero span) to 100µs.
See
"X Offset"
on page 212
.
Selects the measurement window.
Selects the limit line.
Numeric value that defines the distance of the shift.
The unit depends on the scale of the x-axis.
Remote Control
Remote Commands in Receiver Mode
710

Hide quick links:

Advertisement

Table of Contents
loading