R&S ESR Series User Manual page 282

Emi test receiver
Table of Contents

Advertisement

®
R&S
ESR
Child Node
DefaultLimitFailMode
Table 6-4: Attributes and child nodes of the Range element (normal ranges)
Child Node
ChannelType
WeightingFilter
Type
Roll Off Factor
Bandwidth
FrequencyRange
Start
Stop
Limit
Start
Stop
User Manual 1175.7068.02 ─ 12
Attribute
Value
InclusiveFlag
false
Absolute | Relative
| Absolute and Rel-
ative | Absolute or
Relative
Attribute
Value
Index
0...19
Name
<string>
Short-
<string>
Name
TX | Adjacent
RRC | CFilter
0...1
<bandwidth in Hz>
<frequency in Hz>
<frequency in Hz>
dBm/Hz | dBm |
dBc | dBr | dB
Value
<numeric_value>
Unit
dBm/Hz | dBm |
dBc | dBr | dB
Value
<numeric_value>
Spectrum Measurements
Parameter Description
Parameter Description
Inde XE s are continuous
and have to start with 0
Name of the range
Short name of the range
Type of the weighting filter
Excess bandwidth of the fil-
ter
Filter bandwidth
Start value of the range
Stop value of the range
A Range must contain
exactly two limit nodes; one
of the limit nodes has to
have a relative unit (e.g.
dBc), the other one must
have an absolute unit (e.g.
dBm)
Power limit at start fre-
quency
Sets the unit of the start
value
Power limit at stop fre-
quency
Measurements
Mand.
Yes
Yes
Mand.
Yes
Only if Referen-
ceChannel con-
tains a name and
the range is the
reference range
No
Yes
Only if Referen-
cePower method
is TX Channel
Power and the
range is the ref-
erence range
Yes
Only if the filter
type is RRC
Only if the filter
type is RRC
Yes
Yes
Yes
Yes
Yes
279