R&S ESR Series User Manual page 867

Emi test receiver
Table of Contents

Advertisement

®
R&S
ESR
Suffix:
<n>
<m>
Parameters:
<State>
Example:
Manual operation:
CALCulate<n>:MARKer<m>:X:SLIMits:ZOOM <State>
This command sets the limits of the marker search range to the zoom area.
Note: The function is only available if the search limit for marker and delta marker is
switched on (see CALCulate<n>:MARKer<m>:X:SLIMits[:STATe]).
Suffix:
<n>
<m>
Parameters:
<State>
Example:
Manual operation:
CALCulate<n>:MARKer<m>:X:SSIZe <StepSize>
This command defines the step size of the rotary knob for marker or delta marker value
changes. It only takes effect in manual operation.
The marker step size is unavailable for statistical measurements.
Suffix:
<n>
<m>
Parameters:
<StepSize>
User Manual 1175.7068.02 ─ 12
Remote Commands in Spectrum Analyzer Mode
.
Selects the measurement window.
Selects the marker.
ON | OFF
*RST:
OFF
CALC:MARK:MIN:AUTO ON
Activates the automatic minimum value search function for
marker 1 at the end of each particular sweep.
See
"Auto Max Peak/Auto Min Peak"
.
irrelevant
irrelevant
ON | OFF
*RST:
OFF
CALC:MARK:X:SLIM:ZOOM ON
Switches the search limit function on.
CALC:MARK:X:SLIM:RIGH 20MHz
Sets the right limit of the search range to 20 MHz.
See
"Use Zoom Limits"
.
irrelevant
irrelevant
STANdard
step size corresponds to space between two pixels
POINts
step size corresponds to space between two measured values
on page 412