[SENSe:]SCAN<range>:STOP
[SENSe:]SCAN<range>:TIME
[[SENSe:]SWEep:SPACing
[SENSe:]SCAN<range>:BANDwidth:RESolution <Bandwidth>
This command defines the measurement bandwidth for a particular scan range.
Suffix:
<range>
Parameters:
<Bandwidth>
Example:
[SENSe:]SCAN<range>:INPut:ATTenuation <Attenuation>
This command defines the attenuation level for a particular scan range.
Suffix:
<range>
Parameters:
<Attenuation>
Example:
[SENSe:]SCAN<range>:INPut:ATTenuation:AUTO <State>
This command turns auto ranging in a particular scan range on and off.
Suffix:
<range>
Parameters:
<State>
Example:
User Manual 1175.7068.02 ─ 12
........................................................................................ 677
......................................................................................... 678
............................................................................................. 678
.
1...10
Selects the scan range.
Range:
10 Hz to 10 MHz
*RST:
9 kHz
SCAN4:BAND:RES 1MHz
Defines a measurement bandwidth of 1 MHz for the 4th scan
range.
.
1...10
Selects the scan range.
dBmin to dBmax
Range:
Att(min) to Att(max)
*RST:
10 dB
SCAN4:INP:ATT 30dB
Defines an attenuation level of 30 dB for the 4th scan range.
.
1...10
Selects the scan range.
ON | OFF
*RST:
OFF
SCAN4:INP:ATT:AUTO OFF
Turns off auto ranging in the 4th scan range.
Remote Control
Remote Commands in Receiver Mode
675