4 MCP Alarms (Y)
Y05
Initial parameter error
Details
There is a problem in the value set for the number of axes or the number of part systems.
Remedy
Correct the value set for the following corresponding parameters:
"#1001 SYS_ON (System validation setup)",
"#1002 axisno (Number of axes)",
"#1039 spinno (Number of spindles)", etc.
"#2187 chgPLCax (PLC axis switchover axis No.)", etc.
Make sure that the parameters unavailable for a switchover axis (#1068 slavno, #12800 chgauxno, etc.)
are OFF.
Y05
Initial parameter error
Details
The parameter setting of the multiple axis synchronization control is incorrect.
The sub-number is displayed after the error number.
0002:
More than three sets combining the synchronization control and the multiple axis synchronization control are
set.
0003:
The slave axis of multiple axis synchronization control overlaps with the synchronization control axis.
0004:
The master axis of multiple axis synchronization control overlaps with the synchronization control axis.
0005:
The master axis is set to the axis which crosses the part system.
0006:
The slave axis setting is also set to the master axis.
0007:
The function which cannot be used with the multiple axis synchronization control is enabled.
Remedy
Correct the parameter setting.
Y06
mcp_no setting error
Details
There is a skipped number in the channels.
Remedy
Check the values set for the following parameters.
"#1021 mcp_no (Drive unit I/F channel No. (servo))"
"#3031 smcp_no (Drive unit I/F channel No. (spindle))"
Y06
mcp_no setting error
Details
There is a duplicate setting for random layout.
Remedy
Check the values set for the following parameters.
"#1021 mcp_no (Drive unit I/F channel No. (servo))"
"#3031 smcp_no (Drive unit I/F channel No. (spindle))"
Y06
mcp_no setting error
Details
The drive unit fixed setting "0000" and random layout setting "****" are both set.
Remedy
Check the values set for the following parameters.
"#1021 mcp_no (Drive unit I/F channel No. (servo))"
"#3031 smcp_no (Drive unit I/F channel No. (spindle))"
(Parameter No.)
2674
0001
0002
0003
69
(Sub-number)