M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#12890
aux_PSW10dog2
Set "PSW10 area setting" 1 and 2 to specify the area where the position switch 10 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12891
aux_PSW11dog1
Set "PSW11 area setting" 1 and 2 to specify the area where the position switch 11 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12892
aux_PSW11dog2
Set "PSW11 area setting" 1 and 2 to specify the area where the position switch 11 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12893
aux_PSW12dog1
Set "PSW12 area setting" 1 and 2 to specify the area where the position switch 12 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12894
aux_PSW12dog2
Set "PSW12 area setting" 1 and 2 to specify the area where the position switch 12 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12895
aux_PSW13dog1
Set "PSW13 area setting" 1 and 2 to specify the area where the position switch 13 will turn ON when the
machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
IB-1501279-H
PSW10 area setting 2
PSW11 area setting 1
PSW11 area setting 2
PSW12 area setting 1
PSW12 area setting 2
PSW13 area setting 1
682