Mitsubishi Electric M800 Series Manual page 386

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#12052
Jerk_filtG0
Specify the time constant of filter that is used for smoothing the change of jerk when pre-interpolation accel-
eration/deceleration is performed in cutting feed.
This filter causes no path error, as the filter is applied to the total speed calculated before interpolation.
If you specify the jerk filter time constant, the time constants of each filter will be as follows:
* S-shape filter time constant
"#1569 SfiltG0" - "Jerk_filtG0"
* Jerk filter time constant
"Jerk_filtG0"
---Setting range---
0 to 50 (ms)
#12053
EachAxAccCntrl
Select how to calculate the deceleration speed for a corner between the blocks where the high-accuracy con-
trol is enabled.
0: Optimal corner deceleration
(calculate the deceleration speed using the acceleration tolerance common for all the axes determined
by G1bF and G1btL)
1: Per-axis acceleration tolerance control
(calculate the deceleration speed using acceleration tolerances of each axis determined by G1bFx and
G1btLx)
(PR)
#12054
Tol-Ofsnum
Specify the number of offset sets to be allocated when the arbitrary allocation method is selected for offset
sets.
---Setting range---
0 to 999
(PR)
#12055
Tol-lifenum
Specify the number of life management tools to be allocated when the arbitrary allocation method is selected
for life management tools.
---Setting range---
0 to 1000
#12056
I_G0ol
Select the state (enabled or disabled) of the rapid traverse overlap function after reset.
0: Disabled
1: Enabled
---Setting range---
0/1
#12057
OT_prechkON
[M8]
Select the entry inhibition area for stroke check before travel.
0: Perform stroke check before travel for the area specified by G22.
1: Perform stroke check before travel for the area set by the stored stroke limit function, with or without
G22.
[C80]
Not used.
G00 jerk filter
Enable per-axis acceleration tolerance control
Number of tool offset sets for allocation
Number of life management tools for allocation
Enable G00 initial rapid traverse overlap
Enabling stroke check before travel for stored stroke
limit
369