M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#12051
Jerk_filtG1
Specify the time constant of filter that is used for smoothing the change of jerk when pre-interpolation accel-
eration/deceleration is performed in cutting feed.
This filter causes no path error, as the filter is applied to the total speed calculated before interpolation.
If you specify the jerk filter time constant, the time constants of each filter will be as follows:
* S-shape filter time constant
"#1568 SfiltG1" - "Jerk_filtG1"
* Jerk filter time constant
"Jerk_filtG1"
---Setting range---
0 to 50 (ms)
#12066
Tolerance ctrl ON
Select whether to enable the tolerance control.
0: Disable
1: Enable
(Note) Tolerance control is available only under SSS control.
To enable SSS control, set #8090 to 1.
#12070
Sfilt2_tol
Specify the time constant of the filter that smoothes out fluctuations in acceleration under the tolerance con-
trol.
Basically set to 0.
---Setting range---
0 to 200 (ms)
G01 jerk filter
Tolerance control: Soft acceleration/deceleration filter