13 Smart Safety Observation Alarm (V)
V03

User safety sequence 2 error

Details
An error has occurred in User safety sequence 2. The screen displays the error cause.
Safety observation target axes are stopped.
User safety sequences 1 and 2 are both stopped.
All the DOs of the connected safety I/O unit are turned OFF.
Remedy
Refer to the list of user safety sequence error details in Smart safety observation Specification manual.
Cancel the error based on the displayed error cause, and then turn OFF and ON the NC power.
V03

Output sig. cross check error

Details
The signals output to the safety I/O unit are unmatched between PLC1 and PLC2. The screen shows the unit
No., RIO system and signal bit in error.
[M8]
bit24-27: Unit No.
bit16-17: Detected system
bit0-15: Signal BIT
[C80]
bit0-31: Signal BIT
The axes covered by safety function come to a standstill.
Remedy
Check the user safety sequence to make sure the output signal control circuit is correct.
Set tolerable time more than 300ms, when an output signal is controlled with 100ms timer.
NC unit may be faulty. Replace the NC unit.
V04
Safety observation & Smart both ON
Details
The system has both an axis for which Safety observation is enabled (the parameter "#2313 SV113(SSF8)/
bitF" or "#13229 SP229(SFNC9)/bitF" is ON) and an axis for which Smart safety observaiton is enabled (the
parameter "#51101 SF_Disable" or "#51301 SF_SDisable" is OFF).
Remedy
Disable Safety observation for all the axes (Set the parameters "#2313 SV113(SSF8)/bitF" and "#13229
SP229(SFNC9)/bitF" to OFF), and turn ON the NC reset signal.
Disable Smart safety observation for all the axes (Set the parameters "#51101 SF_Disable" and "#51301
SF_SDisable" to OFF), and turn the power OFF and ON.
V04

Safety IO device unconnectable

Details
A safety I/O unit has been connected with the smart safety observation option OFF or with the parameters
"#51101 SF_Disable" and "#51301 SF_SDisable" set to ON for all the axes.The screen displays the channel
to which the safety I/O unit is connected by the bit number.
bit0: Operation panel
bit1: RIO 1CH
bit2: RIO 2CH
bit3: RIO 3CH
Remedy
Disconnect the safety I/O unit, and then turn OFF and ON the power.
If you wish to use Smart safety observation, implement the following and then turn the power OFF and ON.
- Enable the option.
- Turn OFF the axis parameter of Smart safety observation ("#51101 SF_Disable" / "#51301 SF_SDisable").
0014
0015
0001
0002
167
Error cause number
Unit info
Safety I/O unit-connect-
ed channel
IB-1501279-H