M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1086
G0lntp
Select the G00 travel path type.
0: Move linearly toward the end point. (interpolation type)
1: Move to the end point of each axis at the rapid traverse feedrate for each axis. (non-interpolation)
(Note) If this parameter is set to "1", neither of the following functions will be available: rapid traverse constant
inclination acceleration/deceleration and rapid traverse constant inclination multi-step acceleration/decel-
eration.
#1109
subs_M
Select the user macro interrupt with the substitute M code.
0: Disable alternate M code
1: Enable alternate M code
#1110
M96_M
Set an M code to replace M96 when "#1109 subs_M" is set to "1".
---Setting range---
3 to 97 (excluding 30)
#1111
M97_M
Specify an M code to replace M97 when #1109 subs_M is set to "1".
---Setting range---
3 to 97 (excluding 30)
#1148
I_G611
Select the modal state at power ON from among the following: high-accuracy control mode, high-speed high-
accuracy control I mode, high-speed high-accuracy control II mode or high-speed high-accuracy control III
mode.
0: G08P0/G64 (cutting) mode
1: G08P1/G61.1 (high-accuracy control) mode
2: G05.1Q1 (high-speed high-accuracy control I) mode
3: G05P10000 (high-speed high-accuracy control II) mode
4: G05P20000 (high-speed high-accuracy control III) mode
#1151
rstint
Select whether to initialize (power ON state) the modals by resetting.
0: Not initialize modal state
1: Initialize modal state
#1169
part system name
Set the name of each part system.
This must be set only when using multi-part system.
This name will be displayed on the screen only when the part systems must be identified.
Use a max. of four alphabetic characters or numerals.
---Setting range---
A max. of four alphabetic characters or numerals.
#1170
M2name
Set this address code when using the 2nd miscellaneous command. Set an address with A, B or C that is not
used for "#1013 axname" or "#1014 incax".
---Setting range---
A, B, C
#1171
taprov
Set the tap return override value for the synchronous tapping.
When "0" is set, it will be regarded as 100%.
---Setting range---
0 to 100 (%)
IB-1501279-H
G00 non-interpolation
Validate alternate M code
M96 alternate M code
M97 alternate M code
Initial hi-precis
Reset initial
Part system name
Second miscellaneous code
Tap return override
348