M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1490
F-bus init delay 2
[M8]
Specify a period of time during which the control does not detect a Fieldbus communication error of the Field-
bus expansion card mounted in the slot EXT4 (or EXT2 for M80/M800S/E80), after startup of the NC is com-
pleted.
Set this in 0.1-second increments.
(Note1) This parameter is enabled for all the communication expansion cards except PROFIBUS-DP com-
munication expansion card and CC-Link expansion card.
---Setting range---
0 to 60000 (0.1s)
#1925
EtherNet
Start or stop the Ethernet communication function.
0: Stop
1: Start
(PR)
#1926
Global IP address
Set the main CPU's IP address.
Set the NC IP address seen from an external source.
---Setting range---
Set these parameters in accordance with the network rules in the connection environment.
(PR)
#1927
Global Subnet mask
Set the subnet mask for the IP address.
---Setting range---
Set these parameters in accordance with the network rules in the connection environment.
(PR)
#1928
Global Gateway
Set the IP address for the gateway.
---Setting range---
Set these parameters in accordance with the network rules in the connection environment.
#1929
Not used. Set to "0".
#1930
Not used. Set to "0".
(PR)
#1931
Host number
[M8]
Set the host's port No.
---Setting range---
1 to 9999
[C80]
Not used.
(PR)
#1934
Local IP address
[M8]
Set the HMI side CPU's IP address.
---Setting range---
Set these parameters in accordance with the network rules in the connection environment.
[C80]
Not used.
IB-1501279-H
Field bus communication error invalid time 2
Start of service
IP address
Subnet mask
Gateway
Host No.
454