M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2006
G0t2
Not used. Set to "0".
#2007
G1tL
Set a linear control time constant for cutting acceleration and deceleration.
The time constant will be enabled when LC (cutting feed with linear acceleration/deceleration) or F (soft ac-
celeration/deceleration) is selected in "#2003 smgst Acceleration or deceleration modes".
Speed
G1tL
---Setting range---
1 to 4000 (ms)
#2008
G1t1
Set the primary delay time constant for cutting acceleration and deceleration.
The time constant will be enabled when C1 (cutting feed with the primary delay) or C3 (cutting feed with ex-
ponential acceleration and linear deceleration) is selected in "#2003 smgst acceleration/deceleration
modes".
When the soft acceleration or deceleration is selected, the second-step time constant will be used.
<Cutting feed with primary delay>
Speed
G1t1
<Cutting feed with exponential acceleration and linear deceleration>
Speed
G1t1
<Soft acceleration/deceleration>
Speed
G1t1
G1tL
---Setting range---
1 to 5000 (ms)
G1tL
G1t1
2 x G1t1
G1t1 G1t1
G1t1
G1tL
G1 time constant (linear)
Time
G1 time constant (primary delay)/Second-step time con-
stant for soft acceleration/deceleration
Time
Time
Time
471