M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#3039
taps23
Set the speed which switches from 2nd step to 3rd step in synchronous tapping multi-step acceleration/de-
celeration control when gear 10 is selected.
The inclination of linear acceleration/deceleration control for 2nd step is determined by the ratio of
"taps23"(#3039) to "tapt23"(#3043).
When the inclination is not set for 3rd step or it is higher than that of 2nd step, the acceleration/deceleration
control is executed with the same inclination as the 2nd step for the rotation speed of "taps23" or higher.
---Setting range---
0 to 99999 (r/min)
#3040
taps24
Set the speed which switches from 2nd step to 3rd step in synchronous tapping multi-step acceleration/de-
celeration control when gear 11 is selected.
The inclination of linear acceleration/deceleration control for 2nd step is determined by the ratio of
"taps24"(#3040) to "tapt24"(#3044).
When the inclination is not set for 3rd step or it is higher than that of 2nd step, the acceleration/deceleration
control is executed with the same inclination as the 2nd step for the rotation speed of "taps24" or higher.
---Setting range---
0 to 99999 (r/min)
#3041
tapt21
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control when gear
00 is selected.
---Setting range---
1 to 5000 (ms)
#3042
tapt22
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control when gear
01 is selected.
---Setting range---
1 to 5000 (ms)
#3043
tapt23
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control when gear
10 is selected.
---Setting range---
1 to 5000 (ms)
#3044
tapt24
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control when gear
11 is selected.
---Setting range---
1 to 5000 (ms)
#3045
tapt31
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when gear 00
is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of slim-
it1(#3001) to tapt31(#3045).
---Setting range---
1 to 5000 (ms)
IB-1501279-H
Synchronous tapping 2nd step rotation speed (Gear:
10)
Synchronous tapping 2nd step rotation speed (Gear:
11)
Synchronous tapping 2nd step acceleration/decelera-
tion time constant (Gear: 00)
Synchronous tapping 2nd step acceleration/decelera-
tion time constant 2 (Gear: 01)
Synchronous tapping 2nd step acceleration/decelera-
tion time constant (Gear: 10)
Synchronous tapping 2nd step acceleration/decelera-
tion time constant (Gear: 11)
Synchronous tapping 3rd step acceleration/decelera-
tion time constant (Gear: 00)