M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#24021+40(n-1)
[M8]
Set the refresh device No. of the remote register (RWw) to be automatically refreshed.
"n" represents the expansion slot No.(n=1 to 3)
(Note 1) When setting parameters in ALL.PRM with using the parameter input/output function, input the de-
vice No. of decimal digit.
(Example) When setting "X400" for the remote input (RX) refresh device No., input as follows; #24014+40(n-
1): "X" #24015+40(n-1): "1024"
(Note 2) When the refresh device name has been set, the refresh device No. will be "0".Confirm the refresh
device No. after changing the refresh device name.
When specifying a bit device, set the address in increments of 16 points.
The operation will not be guaranteed unless the address is set in increments of 16 points.
(Example) 1FF0
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
M: 0 to 10239
L: 0 to 511
B: 0 to 1FFF
D: 0 to 2047
W: 0 to 1FFF
R: 8300 to 9799, 9800 to 9899
#24022+40(n-1)
[M8]
Set the refresh device name of the special relay (SB) to be automatically refreshed.
(Example) SB
"n" represents the expansion slot No.(n=1 to 3)
Set "0" when no setting is required.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
0,M,L,B,D,W,R,SB
SLn RWw dev No.
SLn SB dev name
667
Remote register (RWw) refresh device No.
Special relay (SB) refresh device name