M00
Aux ax dog overrun
Details
When executing dog-type reference position, the zero point return speed is too fast or the dog length is too
short.
Remedy
Lower the zero point return speed or increase the dog length.
M00
Aux ax R-pnt direction illegal
Details
When executing reference position return, the axis was moved in the opposite of the designated direction.
Remedy
Move the axis in the correct direction.
M00
Aux ax external interlock
Details
The axis interlock function is valid.
Remedy
Cancel the interlock signal.
M00
Aux ax internal interlock
Details
An interlock was established by the servo OFF function.
Remedy
Cancel the servo OFF.
M00
Aux ax soft limit
Details
The stored stroke limit was reached.
Remedy
Check the stored stroke limit setting and machine position.
M00
Aux ax R ret invld at abs alm
Details
Reference position return was executed during an absolute position alarm.
Remedy
Initialize the absolute position reference point and then fix the absolute position coordinates.
M00
Aux ax R ret invld at ini
Details
Reference position return was executed during absolute position initial setting.
Remedy
Initialize the absolute position reference point and then fix the absolute position coordinates.
M01
Dog overrun
Details
When returning to the reference position, the near-point detection limit switch did not stop over the dog, but
overran the dog.
Remedy
Increase the length of the near-point dog.
Reduce the reference position return speed.