M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#13231
SP231
Not used. Set to "0000".
#13232
SP232
Not used. Set to "0000".
#13233
SP233 IVC
When 100% is set, the voltage equivalent to the logical non-energized time will be compensated.
When "0" is set, 100% compensation will be performed.
Adjust in increments of 10% from the default value 100%.
If the value is too large, vibration or vibration noise may be generated.
---Setting range---
0 to 255 (%)
#13234
SP234
Not used. Set to "0".
(PR)
#13235
SP235 R2H
Set the magnification in converting the thermistor temperature to the control compensation amount.
When "0" is set, the temperature compensation function is disabled.
When not using, or when using an IPM spindle motor, set to "0".
---Setting range---
0 to 400 (%)
(PR)
#13236
SP236 WIH
Set the delay time constant from the thermistor temperature to the control compensation amount.
When "0" is set, the delay time constant is disabled.
When not using, or when using an IPM spindle motor, set to "0".
---Setting range---
0 to 150 (min)
(PR)
#13237
SP237 TCF
Set the filter for the torque command.
The standard value is "500".
---Setting range---
0 to 5000 (rad/s)
(PR)
#13238-
SP238-SP240
13240
Not used. Set to "0".
(PR)
#13241-
SP241-SP256
13256
This is automatically set by the NC system.
IB-1501279-H
Voltage non-sensitive band compensation
Temperature compensation gain
Temperature compensation time constant
Torque command filter