16 Machine Parameters
#82007
Select whether to hold or clear the cyclic data output when the PLC is put in STOP status.
0: Output
1: Clear
#82008
Select whether or not to use the loopback function.
When ring topology is selected as the method of connecting with other stations, select "1" (Use).
For the other connection methods, select "0" (Not use).
If the NC acts as a local station, set "0" in the parameter.
If the NC acts as a local station, it operates according to the loopback function setting of master station.
0: Not use
1: Use
#82040
Specify the number of SB link devices for link refresh.
Set this in increments of 16.
---Setting range---
0 to 512
#82041
Specify the start device No. of SB link devices that perform link refresh.
Set the number in increments of 16.
---Setting range---
0 to 1F0 (hexadecimal)
#82042
Specify the project No. of PLC devices that perform link refresh with the SB link devices.
---Setting range---
0 to 6
0: No setting
#82043
Specify the name of PLC devices that perform link refresh with the SB link devices.
---Setting range---
0, M, L, B, D, W, R, SB
0: No setting
#82044
Specify the start device No. of PLC devices that perform link refresh with the SB link devices.
If you designate bit devices, set the number in increments of 16.
---Setting range---
M: 0 to 61424
L: 0 to 32752
B: 0 to EFF0
D: 0 to 32767
W: 0 to 7FFF
SB: 0 to 7FF0
R: 8300 to 9799, 9800 to 9899, 18300 to 19799, 19800 to 19899, 28300 to 29799, 29800 to 29899
#82050
Specify the number of SW link devices for link refresh.
Set this in increments of 4.
---Setting range---
0 to 512
#1 PLC Stop Output
#1 Loopback Func
#1 SB Link-d size
#1 SB Link-d DNo.
#1 Refr-d PNo.(SB)
#1 Refr-d name(SB)
#1 Refr-d DNo.(SB)
#1 SW Link-d size
715
Output setting at PLC STOP
Loopback function setting
Number of SB link devices
Start device No. of SB link devices
Refresh device project No. for SB link device
Refresh device name for SB link device
Refresh device start device No. for SB link device
Number of SW link devices