16 Machine Parameters
#3068
symtm1
Set the time to confirm that synchronization is attained before spindle phase synchronization control is start-
ed.
When "0" is set, the time will be 500ms. When "100" or less is set, the time will be 100ms.
---Setting range---
0 to 9999 (ms)
#3069
symtm2
Set a period of waiting time for spindle phase synchronization control's completion as a time in which the
speed stays within the attainment range.
When "0" is set, the time will be 500ms. When "100" or less is set, the time will be 100ms.
---Setting range---
0 to 9999 (ms)
#3070
syprt
Set the amount of speed fluctuation of synchronous spindle during spindle phase synchronization control.
Set this as a proportion to commanded speed.
When "0" is set, the amount will be 5%.
---Setting range---
0 to 100 (%)
(PR)
#3071
SscDrSelSp
Select which door group of the speed monitoring a spindle belongs to.
0000: Belong to the door 1 group.
0001: Belong to the door 1 group.
0002: Belong to the door 2 group.
0003: Belong to the door 1 and 2 groups.
(Note) Speed monitoring function is validated when "SP229/bitF=1".
---Setting range---
0000 to 0003 (HEX)
(PR)
#3072
Ssc Svof Filter Sp
Set the error detection time for when an error of command speed monitoring or feedback speed monitoring
is detected during servo OFF.
The alarm will occur if actual speed exceeds safe speed or safe rotation speed for a period of time longer
than this setting.
When "0" is set, the detection time will be 200 (ms).
(Note) Speed monitoring function is validated when "SP229/bitF=1".
---Setting range---
0 to 9999 (ms)
#3074
GBsp
Set the reference spindle and G/B spindle.
1: Reference spindle
2: Guide bushing spindle
0: Other
(PR)
#3077
Sname
Specify a spindle name to be used for giving a spindle command.
When spindle command name has been set for all the spindles, the spindle name type is used. If 0 is set to
any spindle, the spindle No. type is selected.
(Note) Do not set an identical name to two or more of all the spindles.
---Setting range---
0 to 9
IB-1501279-H
Phase synchronization start confirmation time
Phase synchronization end confirmation time
Phase synchronization alignment speed
Speed monitor Door selection
Speed monitor Error detection time during servo OFF
Guide bushing spindle synchronization control
Spindle command name