M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
16.32.2 EtherNet/IP Parameters Scanner 2
#81280+10(c-1)
Specify the PLC project No. that is assigned to node. (c=1 to 16)
This number is set as the project No. of PLC device to which the node input/output/control structure is as-
signed.
---Setting range---
1 to 6
#81281+10(c-1)
Specify the name of PLC device to which "Explicit Message control structure" is assigned. (c=1 to 16)
Example) M
---Setting range---
M, L, SB, B, SW, D, R, W
#81282+10(c-1)
Specify the top No. of PLC device to which "Explicit Message control structure" is assigned. (c=1 to 16)
If you specify bit device, set it in increments of 16 points.
Example) 2048
---Setting range---
M: 0 to 61424
L: 0 to 32752
SB:0 to 7FF0
B: 0 to EFF0
SW: 0 to 7FFF
D:0 to 32767
W: 0 to 7FFF
R: 8300 to 9799, 9800 to 9899, 18300 to 19799, 19800 to 19899, 28300 to 29799, 29800 to 29899
CH01 Project No.
CH01 ctrl dev name
CH01 ctrl dev No.
709
Scanner function Explicit Message: PLC project No.
Scanner function Explicit Message: control structure
assign PLC device name
Scanner function Explicit Message: ctrl structure as-
sign PLC device top No.
IB-1501279-H