Base Common Parameters; Spinno; M_Inch - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters

16.3 Base Common Parameters

#1038
plcsel
Not used. Set to "0".
(PR)
#1039

spinno

Select the number of spindles.
0: No spindle
1 to 8: One to eight spindles
(Note) The setting range differs according to the model.
(PR)
#1040

M_inch

Select the unit system for setting and display regarding machine parameter and PLC interface's position,
length and speed.
0: Metric system
1: Inch system
(PR)
#1041
l_inch
Select the unit system for the program travel amount when the power is turned ON or reset and for position
display.
0: Metric system
1: Inch system
(Note) The units of the following data are converted by "#1041 I_inch".
- Command unit at power ON and reset (Inch/metric command mode)
But under the following conditions, the unit will follow G20/G21 command modal even at reset.
When reset modal is retained ("#1151 rstint"="0")
When G code group 06 reset modal is retained ("#1210 RstGmd/bit5" ON)
- Unit system for position display (counter, user parameter, tool, work offset)
- User parameter I/O unit
- Parameter unit of user parameters concerning length and speed
- Arc error parameter (#1084 RadErr)
(PR)
#1042
pcinch
Select the unit system for the commands to the PLC axis.
0: Metric system
1: Inch system
Ladder selection
Number of spindles
Constant input (inch)
Initial state (inch)
PLC axis command (inch)
379