15 User Parameters

15.6 Axis Parameters

#1063
mandog
Select the manual reference position return method for the second return (after the coordinate system is es-
tablished) and later.
The initial reference position return after the power ON is performed with dog-type return, and the coordinate
system will be established.
(This setting is not required when the absolute position detection is used.)
0: High speed return
1: Dog-type
#8201

AX. RELEASE

Select the function to remove the control axis from the control target.
0: Control as normal.
1: Remove from control target.
#8202

OT-CHECK OFF

Select whether to enable the stored stroke limit II function set in #8204 and #8205.
0: Enable
1: Disable
#8203

OT-CHECK-CANCEL

When the simple absolute position method ("#2049 type" is "9") is selected, the stored stroke limits I, II (or
IIB) and IB can be disabled until the first reference position return is executed after the power is turned ON.
0: Enable (according to #8202)
1: Temporarily cancel
(Note) "#8203 OT-CHECK-CANCEL" affects all the stored stroke limits.
#8204
OT-CHECK-N
Set the coordinates of the (-) direction in the movable range of the stored stroke limit II or the lower limit co-
ordinates of the prohibited range of stored stroke limit IIB.
If the sign and value are the same as #8205, the stored stroke limit II (or IIB) will be invalid.
If the stored stroke limit IIB function is selected, the prohibited range will be between two points even when
#8204 and #8205 are set in reverse. When II is selected, the entire range will be prohibited if #8204 and
#8205 are set in reverse.
---Setting range---
-99999.999 to 99999.999 (mm)
#8205
OT-CHECK-P
Set the coordinates of the (+) direction in the movable range of the stored stroke limit II or the upper limit
coordinates of the prohibited range of stored stroke limit IIB.
---Setting range---
-99999.999 to 99999.999 (mm)
#8206
TOOL CHG. P
Set the coordinates of the tool change position for G30. n (tool change position return).
Set with coordinates in the basic machine coordinate system.
---Setting range---
-99999.999 to 99999.999 (mm)
#8207
G76/87 IGNR (for M system only)
Select whether to enable the shift operation at G76 (fine boring) and G87 (back boring).
0: Enable
1: Disable
Manual dog-type
251