Grspcref - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2040
#4_rfp
Set the position of the fourth reference position from the zero point of the basic machine coordinate.
---Setting range---
-99999.999 to 99999.999 (mm)
#2041

grspcref

[M8]
Select the reference encoder (motor-end or machine-end) based on which the grid interval "#2029 grspc" is
set.
0: Motor-end
1: Machine-end
(Note) When an MPI scale made by Mitsubishi Heavy Industries Machine Tool Co., Ltd. is used, set the zero
point return parameters so that Z phase of the MPI scale becomes the grid point (electric basic position),
and then perform zero point initialization setting.
[C80]
Not used.
IB-1501279-H
Reference position #1
(#2037 G53ofs)
Reference position #2
(#2038 #2_rfp)
Reference position #3
(#2039 #3_rfp)
510
Reference position #4
Basic machine coordinate
Reference position #4
(#2040 #4_rfp)
Reference encoder for grid interval

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents