M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
M01
Prog check: machine posn error
Details
When the NC reset signal is input with the High-speed simple program check: Coordinate position check ON
signal (Y76B) set to ON, the machine coordinate position is different from the position at the program start.
Remedy
Correct the machining program.
M01
NC/PLC axis switch illegal
Details
The following operation was performed to an axis which can be switched over between NC axis and PLC axis.
PLC axis switchover signal was turned ON or OFF when it was prohibited to switch over the axis.
Remedy
Make sure the axis switchover status signal is OFF and change the ON/OFF of the axis switchover signal.
M01
No spec: Multi axis synch ctrl
Details
You have set the R register for selecting synchronous control operation method, although the option of multiple
axis synchronization control is OFF.
Remedy
Set 0 in R2589 (Synchronous control operation method selection).
M01
Multiple secondary ax selected
Details
For the multiple axis synchronization control, you selected two or more slave axes without selecting any master
axis.
Remedy
Correct the setting of R2589 (Synchronous control operation method selection).
M03
Interference detection
Details
A command has been given that causes two or more objects to interfere with each other.
yy : Interference object definition number (1)
zz : Interference object definition number (2)
Remedy
Cancel the alarm with reset.
Disable the interference check III mode first before moving the interfering object further in the interference
direction.
M03
Entry in interfere alarm area
Details
Two or more interfering objects are in the interference alarm area.
yy : Interference object definition number (1)
zz : Interference object definition number (2)
Remedy
Disable the interference check III mode before moving.
Check the interference definition and the interference selection.
M03
Entry in interfere warn area
Details
A command has been given that causes two or more interfering objects to enter the interference warning area.
yy : Interference object definition number (1)
zz : Interference object definition number (2)
Remedy
Interfering objects are in the interference warning area.
If an operational problem is expected to occur, stop moving the axes with feed hold, cancellation of manual axis
movement or reset.
IB-1501279-H
0001
0002
0003
34
1216
1250
1254
1255
yyzz
yyzz
yyzz