M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters

16.32.3 EtherNet/IP Parameters Adapter 1

#81440+20(a-1)
Specify the PLC project No. that is assigned to Adapter Implicit (IN/OUT) area. (a=1 to 6)
This number is set as the project No. of PLC device for input/output to/from Adapter Implicit (IN/OUT) area.
---Setting range---
1 to 6
#81441+20(a-1)
Specify the offset (bytes) from the head of Adapter Implicit (IN) area. (a=1 to 6)
The data starting from the specified offset is sent from Adapter Implicit (IN) area to PLC device.
Example) 100
---Setting range---
0 to 499 (bytes)
#81442+20(a-1)
Specify the name of PLC device to which Adapter Implicit (IN) area data is transferred. (a=1 to 6)
Example) X
---Setting range---
X, M, L, SB, B, SW, D, R, W
#81443+20(a-1)
Specify the top No. of PLC device to which Adapter Implicit (IN) area data is transferred. (a=1 to 6)
If you specify bit device, set it in increments of 16 points.
Example) 200
---Setting range---
X: 0 to 5F0
M: 0 to 61424
L: 0 to 32752
SB: 0 to 7FF0
B: 0 to EFF0
SW: 0 to 7FFF
D: 0 to 32767
W: 0 to 7FFF
R: 8300 to 9799, 9800 to 9899, 18300 to 19799, 19800 to 19899, 28300 to 29799, 29800 to 29899
#81444+20(a-1)
Specify the size (bytes) of Adapter Implicit (IN) area data that is transferred to PLC device. (a=1 to 6)
Example) 1
---Setting range---
0 to 500 (bytes)
* Up to 500 bytes in total for all areas
#81445+20(a-1)
Specify the offset (bytes) from the head of Adapter Implicit (OUT) area. (a=1 to 6)
The PLC device data starting from the specified offset is sent to Adapter Implicit (OUT) area.
Example) 100
---Setting range---
0 to 499 (bytes)
IB-1501279-H
Imp A1 Proj No.
Imp A1in offset
Imp A1in dev name
Imp A1in dev No.
Imp A1in dev size
Imp A1out offset
710
Adapter function Implicit Message: PLC project No.
Adapter function Implicit Message: IN area top offset
Adapter function Implicit Message: PLC device name
(IN)
Adapter function Implicit Message: PLC device top No.
(IN)
Adapter function Implicit Message: PLC device size (IN)
Adapter function Implicit Message: OUT area top offset