M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P182
Synchronous tap error
Details
Connection to the main spindle unit was not established.
The synchronous tapping was attempted with the spindle not serially connected under the multiple-spindle
control I.
Synchronous tapping command was given to the analog spindle while analog spindle synchronous tapping
was unavailable.
Remedy
Check connection to the main spindle.
Check that the main spindle encoder exists.
Set 1 to the parameter #3024 (sout).
Correct the program.
P183
No pitch/thread number
Details
The pitch or number of threads has not been commanded in the tap cycle of a fixed cycle for drilling command.
Remedy
Specify the pitch data and the number of threads by F or E command.
P184
Pitch/thread number error
Details
The pitch or the number of threads per inch is illegal in the tap cycle of the fixed cycle for drilling command.
The pitch is too small for the spindle rotation speed.
The thread number is too large for the spindle rotation speed.
Remedy
Correct the pitch or the number of threads per inch.
P185
No spec: Sync tapping cycle
Details
Synchronous tapping cycle (G84/G74) was commanded though it is out of specifications.
Remedy
Check the specifications.
P186
Illegal S cmnd in synchro tap
Details
S command was issued during synchronous tapping modal.
Remedy
Cancel the synchronous tapping before issuing the S command.
P190
No spec: Turning cycle
Details
A lathe cutting cycle command was issued though it is out of specifications.
Remedy
Check the specification.
Delete the lathe cutting cycle command.
P191
Taper length error
Details
In the lathe cutting cycle, the specified length of taper section is illegal.
Remedy
Set the smaller radius value than the axis travel amount in the lathe cycle command.
P192
Chamfering error
Details
Chamfering in the thread cutting cycle is illegal.
Remedy
Set a chamfering amount not exceeding the cycle.
135