Mitsubishi Electric M800 Series Manual page 71

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
3 Servo/Spindle Alarms (S)
004D.xxx : Alarm number.Sub-number
Sub-No.
Name
65
Register diagnosis error
66
Calculation device
diagnosis error
67
Sequence diagnosis error
68
Stack diagnosis error
69
Temperature diagnosis
error
71
Watchdog error
72
Clock diagnosis error
74
DO output compare error
75
ISC communication error
78
Safety communication:
Initial communication error 3
88
Safety circuit: STO error
91
Safety circuit: SBC error
126
Safety communication:
Communication error 3
IB-1501279-H
Details
A resister diagnosis error was detected in the
safety function.
An error was detected in the calculation
device diagnosis for the safety function.
An error was detected in the sequence
diagnosis for the safety function.
An error was detected in the stack diagnosis
for the safety function.
Overheat was detected in the safety function.
The safety function is not operating correctly.
An error was detected in the clock diagnosis
for the safety function.
An error was detected in the status of DO
output for the safety function.
An error was detected in the inter-system
communication for the safety function.
A receiving error was detected in the initial
communication for the safety communication.
An error was detected in the read-back
diagnosis for STO.
An error was detected in the read-back
diagnosis for SBC.
A receiving error was detected in the safety
communication.
54
Reset
Axis
Servo
method
type
stop method
PR
Each axis
Initial error
PR
Each axis
Initial error
PR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
NR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
PR
Each axis Dynamic stop Coast to a stop
Spindle
stop method
Initial error
Initial error

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents