P-Bus Dev Assign; Mgralmstp; Mgralmrestart; Mgralmcont - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1469

P-BUS dev assign

[M8]
Select how to allocate the PLC devices that are used for PROFIBUS-DP(DPV0):
fixed allocation (512 points) or arbitrary allocation (8192 points).
0: Fixed
1: Arbitrary
(PR)
#1471

mgralmstp

Select whether to enable the machine groupwise alarm stop function.
0: Disable
1: Enable
(PR)
#1472

mgralmrestart

Select whether to allow automatic operation to be activated after machine groupwise alarm stop.
0: Not allow automatic operation to start after machine groupwise alarm stop
1: Allow automatic operation to start after machine groupwise alarm stop
(PR)
#1473

mgralmcont

When any alarm causes an axis that is in the midst of program execution to stop, this parameter allows you
to select the behavior of axes that belong to machine groups other than that of the said axis.
0: Feed hold
1: The operation is allowed to continue.
(PR)
#1474
SBS2_sys num
Specify the number of sub part systems to use in sub part system control II.
The specified number of part systems counted from the end of the system's effective part systems are treated
as sub part systems.
---Setting range---
0 to 7
(PR)
#1475
MES-IF_on
Set whether to enable the MES interface function.
0: Disable
1: Enable
#1476
ComErrDly
[C80]
Specify a period of time by which to delay the alarm display and record to the alarm history, when the com-
munication error (Y02 0051) occurs.
Set this time when a communication error is caused at power OFF.
If it does not occur (if unused), set to 0.
---Setting range---
0 to 5000 (ms)
#1477
SrvAlmDly
[C80]
Specify a period of time by which to delay the alarm display and record to the alarm history, when a servo/
spindle alarm occurs.
Set this time when a servo/spindle alarm is caused at power OFF.
If it does not occur (if unused), set to 0.
---Setting range---
0 to 5000 (ms)
IB-1501279-H
PROFIBUS device allocation method
Enable machine groupwise alarm stop
Allowing automatic operation to start after machine
groupwise alarm stop
Allowing operation to continue after machine group-
wise alarm stop
Number of sub systems to use in sub part system con-
trol II
MES-IF ON
Delayed display of communication alarm
Delayed display of servo alarm
452

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents