M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
(PR)
#8225

Wk coord at R ret.

Workpiece coordinate position displayed right after automatic reference position return
Select whether to apply a range of 0 to 360 degrees to the workpiece coordinate position displayed right after
automatic reference position return if the said position is out of the range of 0 to 360 degrees.
0: Display the position in a range of 0 to 360 degrees
1: Not display the position in a range of 0 to 360 degrees
#8226

Wk position check

Workpiece position check
Select whether to check a difference of workpiece coordinate position between when NC is reset and when
program operation is started, when both High-speed simple program check mode ON (X712) and High-
speed simple program check: Coordinate position check ON (X713) are set to ON.
0: Disable the check
1: Enable the check
#8227

Machine posn check

Machine position check
Select whether to check a difference of machine coordinate command position between when NC is reset
and when program operation is started, when both High-speed simple program check mode ON (X712) and
High-speed simple program check: Coordinate position check ON (X713) are set to ON.
0: Disable the check
1: Enable the check