Special Ax Radius; Special Ax Clamp; Manualfeedbtl; S_Din - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2175

Special Ax Radius

Set the radius of the special diametral axis.
---Setting range---
0 to 99999.999 (mm)
#2176

Special Ax Clamp

Set a clamp speed for the special diametral axis control.
Set the limit speed of the drive system in this parameter.
---Setting range---
0 to 1000000 (°/min)
(Note) For "#2001 rapid" and "#2002 clamp", set speeds on a machining line.
When the value in "#2176 Special Ax Clamp" is smaller than that in "#2001 rapid", "Special Ax Clamp" value
will be applied to the clamp speed.
#2177

ManualFeedBtL

Set the acceleration/deceleration time constant for manual feed rate B.
(Note) When set to "0", this parameter will not be used: conventional acceleration/deceleration will be per-
formed.
---Setting range---
0 to 20000 (ms)
(PR)
#2180

S_DIN

Set the door signal input in the drive unit.
Use this parameter only when the axis with a door signal belongs to several door groups.
The correspondence between the door signals and bits are as follows.
bit0 : Door1 signal
bit1 : Door2 signal
If the axis does not receive any door signal, set to "0".
If 0 is set to the axis to which a door signal is input, the setting of #2118 is applied.
Do not turn ON more than one bit.
Only the door signals set in #2118 can be set.
---Setting range---
0000 to 0002 (HEX)
(PR)
#2181
sscfeed1
Set the observation speed, which is at the machine end, in the multi-step speed monitor.
(Note 1) When the setting value is larger than 18000, the last 2 digits will be ignored.
Ex. 1234567 -> 1234500(mm/min, °/min)
(Note 2) Observation speeds (#2181 to #2186 and #2191 to #2192) need to satisfy the following condition.
If not satisfied, the alarm (Y20 0007) will result.
sscfeed1 8
SV018:PIT
---Setting range---
0 to 6553500 (mm/min or °/min)
IB-1501279-H
SV002:PC2
×
32767
SV001:PC1
490
Special diametral axis radius
Special diametral axis clamp speed
Time constant for manual feed rate B
Speed observation input door No.
Observation speed 1