M800/M80/E80/C80 Series Alarm/Parameter Manual
5 System Alarms (Z)
Z69
External link error
Details
The I/O No. designated in the FROM/TO instruction is different from the mounted location of the intelligent func-
tion module on the extension base (the module's I/O No.).
Remedy
Correct the I/O No. Then turn the CNC's power ON again.
Z82
3D machine interference/No machine model
Details
Machine model is not registered.
Remedy
Press RESET to cancel the alarm.
Movement can be resumed after the cancellation. However, the 3D machine interference check will become
invalid.
Inform the machine tool builder if an alarm occurs.
Z82
3D machine interference/Machine model illegal
Details
Machine model is illegal.
Remedy
Press RESET to cancel the alarm.
Movement can be resumed after the cancellation. However, the 3D machine interference check will become
invalid.
Inform the machine tool builder if an alarm occurs.
Z82
3D machine Interference check load excess
Details
The calculation of the interference check took time and caused a deceleration.
Remedy
Inform the machine tool builder.
Restart the axis in case of a manual operation.
In case of an automatic operation, the operation will automatically resume when the processing load of the
interference check decreases.
Z82
3D machine Interference check error
Details
The interference check failed.
Remedy
Take a note of the failed status and contact the service center.
Press RESET to cancel the alarm. Invalidate the 3D machine interference check to continue the operation.
Z84
Unable to save all the history
Details
The system is unable to store the data due to lack of free space on the internal memory.
Remedy
Ensure sufficient free space on the internal memory.
Z85
OP panel I/O not connected
Details
Failed to recognize the connection between the NC unit and operation panel I/O unit.
Remedy
Make sure an operation panel I/O unit is connected.
Make sure an operation panel I/O unit is supplied with power.
Check for disconnection of the cable between the NC unit and operation panel I/O unit.
*If you connect no operation panel I/O unit to the NC unit, set the parameter "#1261 set33/bit1" to "1"."